Product Description
DARATARD® R1 is liquid retarding admixture for concrete which temporarily delays the hydration of cement allowing the transportation and placing of concrete to be extended. It can be used with all types of concrete, including sprayed concrete. DARATARD® R1 is formulated from carefully selected raw materials and is manufactured under controlled conditions to give a consistent product. It is based on inorganic hydroxylated polymers and conforms to EN934-2 and to Type B of ASTM C494.
Product Advantages
- The degree of retardation is proportional to the dosage used. It is possible, therefore, to produce charts relating dosage to retardation according to the mix design and prevailing site conditions.
- The fully hardened concrete possesses improved physical properties in terms of ultimate strength and concrete to re-inforcement bond strength.
- DARATARD® R1 does not entrain any additional air or plasticise the concrete.
- Predictable retardation of up to several days is possible.
- Conventional concreting and sprayed concreting can be continued under conditions of high ambient temperatures.
- Delivery of concrete can be made over long distances from a ready-mix or site batching plant.
- Cold joints can be eliminated.
- Workability loss in long distance pumping applications can be avoided, particularly when used in conjunction with a Daracem superplasticiser.
Typical Properties
Appearance | Pale straw coloured liquid |
Air Entrainment | Nil |
Chloride Content | Nil as per EN480-10 |
Freezing Point | <-9˚C |
Addition Rates
Range | 300 ml - 3000 ml per 100 kg cement |
Range | 0.3% - 3.0% (v/w) by wt. of cement |
DARATARD® R1 is a versatile product which gives benefits in a wide variety of applications. As with most products of this type, the level of effect of DARATARD® R1 is governed, within limits, by the quantity of product used and the specific nature of the concrete mixture.
The performance of DARATARD® R1 is best assessed after preliminary tests using the actual concrete materials to determine the optimum dosage and effect on both plastic and hardened concrete properties. As a guide to these trials, we recommend an addition of 100ml per 100kg cement for each additional hour of set retardation required.
DARATARD® R1 is supplied ready for use. It should be added to the concrete mix during the mixing cycle with the water, after the addition of the cementitious component. It should not be added directly to the cement. No extension of normal mixing time is required.
Overdosing of DARATARD® R1 will generally produce a considerable increase in set retardation, without any significant increase in air entrainment. In cold weather, this retardation will be further increased. If the increase is above the recommended dosage rate employed, care must be taken to allow for the retardation effect on stripping time and form work pressure. In such cases, however, provided the concrete is properly cured, the ultimate strength will generally be higher than for normal concrete.
Compatibility
With cements:
DARATARD® R1 can be used with Ordinary and Rapid Hardening Portland Cements. The effect produced by a retarding admixture is affected by the nature of the cement. When the cement source or type is changed, field trials should be repeated. For use with Sulphate Resisting Cements or other special cements we recommend that you consult GCP.
With other Admixtures:
DARATARD® R1 should not be premixed with other admixtures. The performance of the material may be affected by the presence of other chemicals and we recommend that you consult GCP Applied Technologies in such circumstances.
Dispensing
DARATARD® R1 is supplied in 205-litre, non-returnable containers. Alternatively, bulk deliveries can be arranged.
Packaging
DARASET® 580C is supplied in 205-litre, non-returnable containers. Alternatively, bulk deliveries can be arranged.
Storage
DARATARD® R1 should be stored above 0˚C and protected from frost. If the product does freeze, it should be carafully thawed before mixing.
Storage life in manufacturer’s drums: 12 months from date of manufacture.
Storage life bulk storage: 12 months from date of delivery.
Health and Safety
See DARATARD® R1 Safety Data Sheet or consult GCP Applied Technologies.
Technical Service
The Technical Service department of GCP Applied Technologies is available to assist you in the correct use of our products.
gcpat.ae | United Arab Emirates customer service: +971 4 5139560
We hope the information here will be helpful. It is based on data and knowledge considered to be true and accurate, and is offered for consideration, investigation and verification by the user, but we do not warrant the results to be obtained. Please read all statements, recommendations, and suggestions in conjunction with our conditions of sale, which apply to all goods supplied by us. No statement, recommendation, or suggestion is intended for any use that would infringe any patent, copyright, or other third party right.
DARATARD is a trademark, which may be registered in the United States and/or other countries, of GCP Applied Technologies Inc. This trademark list has been compiled using available published information as of the publication date and may not accurately reflect current trademark ownership or status.
© Copyright 2018 GCP Applied Technologies Inc. All rights reserved
830-832 Fountains Court Birchwood Boulevard, Birchwood Warrington Cheshire WA3 7QZ
GCP Applied Technologies Inc., 2325 Lakeview Parkway, Alpharetta, GA 30009, USA
P. O. Box 5006, Office 2104, 21 Floor, The Exchange Tower, Opp. JW Marriott Marquis Hotel, Business Bay, Dubai – United Arab Emirates
This document is only current as of the last updated date stated below and is valid only for use in the UAE. It is important that you always refer to the currently available information at the URL below to provide the most current product information at the time of use. Additional literature such as Contractor Manuals, Technical Bulletins, Detail Drawings and detailing recommendations and other relevant documents are also available on www.gcpat.ae. Information found on other websites must not be relied upon, as they may not be up-to-date or applicable to the conditions in your location and we do not accept any responsibility for their content. If there are any conflicts or if you need more information, please contact GCP Customer Service.
Last Updated: 2022-11-18
https://gcpat.ae/en-gb/solutions/products/daratard-r1